Table of Contents

Tracking of Orthopaedic Instruments in 3D Camera Views

Last updated: Mar 8th, 2017 6:09 pm

Summary

Enter a short narrative description here

Background, Specific Aims, and Significance

Kirshner wires or K-wires are long, smooth stainless steel pins that are widely used in orthopedics surgery to hold bones together. The pins are driven through the skin using a power or hand drill. They can be used for temporary fixation before inserting screws or permanent fixation while the bones heal. K-wire and screw insertion is currently done with minimally invasive techniques, involving modern imaging technology and computer aided navigation systems. Correct placement requires numerous intra-operative X-ray images, and often requires multiple attempts before the surgeon achieves satisfactory placement and orientation [1]. Misplacement of the K-wire could cause severe damage to external iliac artery and vein, obturator nerve and other structures [2]. This leads to multiple entry wounds on the patient, high X-ray exposure for the patient and the surgical staff, increased OR time and frustration of the surgical team. A single K-wire insertion could take as much as 10 minutes for a single insertion[3]. The main challenge during K-wire insertion has been identified as the mental alignment of patient, medical instruments and intra-operative X-rays [4]. Recently, camera augmented solutions have been proposed to help surgeons in this mental alignment [5,6].

In this project, we aim to track the K-wire in 3D using stereo RGB cameras with convolutional neuron network.

Deliverables

Technical Approach

Technical Approach:

We propose a real time tracking of the K-wire using on RGB data. Traditional computer vision methods face challenges in this task due to non-uniform lighting, occlusions, and the complex background. Hence deep learning is used to segment the surgical video.

The solution can be divided into three main parts:

1. Data Creation

Large, quality data is essential to training a successful neural network. Since there is no data set available for K-wire tracking, our first step is to create one. We will capture the foreground (K-wire) and background (scene including drape, instruments etc.) separately and compose them in stages to generate data of varying complexity. By capturing the foreground separately on a plain background (Figure 1 a) Sample foreground shot before segmentation (left), we can easily segment the K-wire to obtain soft ground truth for position. We propose to train the network on the simplest data and increment the complexity of the data once we have a basic trained network that can distinguish the K-wire against a plain background. The final step would be to compose a dataset using actual videos from a surgery.

Figure 1 a) Sample foreground shot before segmentation (left). Sample background images (middle and right)

2. Network architecture

A few potential network architectures have been identified.

a. Holistically-nested Edge Detection) for tool segmentation [10]

Figure 3) Schematic of the network architecture

This approach uses three fully convolutional networks (FCN’s) to simultaneously perform 2D multi-class segmentation, binary segmentation and edge detection. Finally Conditional Random Fields are used to refine the mask from the multi-class using outputs from binary segmentation and edge detection.

b. U-Nets [11]

U-Nets have been shown to give good results in biomedical image segmentation. These networks rely on fully convolutional layers to combine features at different resolutions to achieve precise segmentations that retain semantic information. In addition, extensive data augmentation allows use of fewer training samples.

3. Pose Estimation

We will use epipolar geometry to do pose estimation from stereo images. 2D segmentations from the RGB images can be used to know the 3D position of the K-wire with respect to the stereo camera. The cameras will be pre-calibrated with a checkerboard pattern. In capturing our data, we will use an AR tag on the K-wire to create ground truth location for it. The AR tag will then be removed, prior to taking the video.

In our validation dataset, with X-ray and RGBD camera, as in the CamC[12] set up, we will calibrate the two with metal lined checkerboard pattern. The orientation of the K-wire is thus obtained by extending the line to infinity. The final step (maximum deliverable) would be to identify the tip of the K-wire on this infinite line, which could be potentially done by identifying markings on the K-wire.

Timeline

Dependencies

All except one dependency has been resolved. The remaining one “Observe K-wire use in clinic” is dependent on our surgical collaborators, Dr. Alex Johnson and Dr. Greg Osgood. They will inform us if there is an appropriate surgery using K-wires that we can observe. If this dependency is not met, we will still complete our project, but ask Dr. Johnson to set up the scene as close to the real situation as he could using our phantom in the Mock OR and fake blood.

Milestones and Status

  1. Milestone name: Phantom setup
    • Completed Date: 2/26/17
    • Status: Complete
  2. Milestone name: Data set
    • Planned Date: 3/17/17
    • Expected Date: 3/17/17
    • Status: Started collecting some data. Still need to take more videos
  3. Milestone name: CNN initial training (Minimum deliverable)
    • Planned Date: 4/11/17
    • Expected Date: 4/11/17
    • Status: Not started
  4. Milestone name: 3D Position Recovery (Expected deliverable)
    • Planned Date: 4/28/17
    • Expected Date: 4/28/17
    • Status: Not Started
  5. Milestone name: Tip position estimation (Maximum deliverable)
    • Planned Date: 5/15/17
    • Expected Date: 5/15/17
    • Status: Not Started

Reports and presentations

Project Bibliography

Reading list:

  1. Fischer, Marius, et al. “Preclinical usability study of multiple augmented reality concepts for K-wire placement.” International Journal of Computer Assisted Radiology and Surgery 11.6 (2016): 1007-1014.
  2. Jégou, S., Drozdzal, M., Vazquez, D., Romero, A., & Bengio, Y. (2016). The One Hundred Layers Tiramisu: Fully Convolutional DenseNets for Semantic Segmentation. arVix Preprint.
  3. Long, Jonathan, Evan Shelhamer, and Trevor Darrell. “Fully convolutional networks for semantic segmentation.” Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition. 2015.
  4. Pakhmov et. al, Semantic-boundary-driven approach to Instrument Segmentation for Robotic Surgery
  5. Lee et. al, Simultaneous Segmentation, Reconstruction and Tracking of Surgical Tools in Computer Assisted Orthopedics Surgery
  6. Ronneberger, O., Fischer, P., & Brox, T. (2015). U-Net: Convolutional Networks for Biomedical Image Segmentation. In Medical Image Computing and Computer Assisted Intervention - MICCAI 2015 (Vol. 9351, pp. 234–241). Springer, Cham. https://doi.org/10.1007/978-3-319-24574-4_28
  7. Szegedy, C., Reed, S., Erhan, D., Anguelov, D., & Ioffe, S. (2014). Scalable, High-Quality Object Detection. arXiv. Retrieved from http://arxiv.org/abs/1412.1441

References:

Other Resources and Project Files